Pre-filled Syringe Luer Connector Axial Load Resistance Separation Tester

Price:Negotiable
Industry Category: Measurement-Analysis-Instruments
Product Category:
Brand: 众测机电
Spec: LEY-T01


Contact Info
  • Add:济南市高新东区银丰国际生物城园区A3-02, Zip:
  • Contact: 众测机电
  • Tel:0531-88983898
  • Email:1844233077@qq.com

Other Products

Description
Additional Information

Pre-filled syringes are commonly used medical devices for injecting medications or liquids. Among them, the Luer connector is a critical component of pre-filled syringes, responsible for connecting the syringe body and the needle. To ensure the safety and reliability of pre-filled syringes, it is necessary to conduct axial load separation resistance tests on the Luer connector during the manufacturing process.

What testing instrument is used for the axial load separation resistance test of pre-filled syringe Luer connectors?

The Pre-filled Syringe Luer Connector Axial Load Separation Resistance Tester LEY-T01 (commonly known as the Luer Connector Tester), developed and produced by Zhongce Electromechanical, is a specialized device for testing the axial load separation resistance performance of Luer connectors.


Pre-filled Syringe Luer Connector Axial Load Separation Resistance Tester


Pre-filled Syringe Luer Connector Axial Load Separation Tester LEY-T01 Main Parameters

Common Name: Luer Connector Tester

Axial Force: 0-100N

Accuracy: Error not exceeding ±0.5% of reading

Internal Water Pressure: 0Kpa-600Kpa

Accuracy: Error not exceeding ±0.5% of reading

Negative Pressure: -90kpa-0kpa

Accuracy: Error not exceeding ±0.5% of reading

Torque: 0.01N•m~0.50N•m

Accuracy: Error not exceeding ±0.5%

Separation Force: 20-40N (0-100N)

Accuracy: Error not exceeding ±0.5%

Power Supply: AC220V, 50Hz

Dimensions: 580×280×510(mm)

Weight: 28Kg



Testing Method and Operating Steps for the Pre-filled Syringe Luer Connector Axial Load Separation Tester:

First, install the pre-filled syringe to be tested onto the clamping device and adjust the fixture to the appropriate position. Then, secure the Luer connector to the connector clamping device.

Next, connect the load device and the testing device, ensuring a tight and secure connection without any looseness. Then, set the required axial load value for the test and start the control system.

The load device will apply a specific axial load to the Luer connector via a cylinder, while the force sensor records real-time separation force data. During the test, monitor whether the Luer connector separates and the force value at the moment of separation. Based on the test results, determine whether the axial load separation resistance performance of the Luer connector meets the standard requirements.

Using the Pre-filled Syringe Luer Connector Axial Load Separation Tester, the stability and reliability of the Luer connector under load can be evaluated, ensuring that the pre-filled syringe does not experience unexpected breakage or damage during use, thereby safeguarding patient safety.


Related Content on the Pre-filled Syringe Luer Connector Axial Load Separation Tester:http://www.pubtester17.com/pro/539.html


Industry Category Measurement-Analysis-Instruments
Product Category
Brand: 众测机电
Spec: LEY-T01
Stock:
Origin: China / Shandong / Jinanshi
About Toocle.com - Partner Programme - Old Version
Copyright © Toocle.com. All Rights Reserved.
(浙)-经营性-2023-0192